Wednesday, November 5, 2008

FWSM Design & Integration With 6500/7600

Click Here For FWSM Architecture
A big question of FWSM physical integration comes in mind how it is working without the existance of any physical port. Given figure which cleary reveals how blade is integrated with 7600/6500 chassis with 6 Gigabit Ether Channel. Blade consists of network proceeor 1A & Network processor 1B which are further connected to Network processor 2 and bus. NP1A & NP1B can handle upto 3 million packets per second. FWSM Code processor is a software based component which is responsible for layer 7 protocol inspection, neighbors adjacencies and maintains routing information. Traffic processed by NP1A & NP1B is known as fast path. Traffic processed by NP2 is considered the session management path and traffic processes by FWSM code processor is known as slow path.

regards
shivlu jain
Click Here To Read Rest Of The Post...

Tuesday, November 4, 2008

CEF LoadbalancingProblem



Sometimes you may face the problem in which if you ping from R7 to R6 it works perfect but when you try to ping from R5 to R6 you may face drops. Whats the reason for that ? Do you know ?
Needn’t worry about that I will let you know the reason behind this. Actually what happens when you ping from R7 the packets are process switched and then from R5 they are CEF switched because of cef switched by default it takes per destination based. So your packets always path either R5-R3 or R5-R1. Lets assume packets takes R5-R3 path and R5-R1 paths has some CRC errors etc. So in this case your packets will always follow R5-R3 path never R5-R1 and you find no more drops. But in latter case when you ping from R5 to R6, you always find drops because packets originated from R5 always process switched, so packets are always load balanced across both paths and you may drops becasue of this.
You can check with the help of " show ip cef exact-route " command which will tell you which path is being taken by the packets.

Click Here To Download
Click Here To Read Rest Of The Post...

Friday, October 24, 2008

What happen if all SFC removed from GSR

During reading a article on GSR; I was stumbled when come to know that GSR can also work without SFC(Switch Fabric Card). Actually what happens when the SFC removed from the GSR Clock Schedular Card(CSC) comes into the picture. At that time all the line engines will stop work except line engine 0. So your CSC will work as SFC.
what i think that at that time all line engines are stopped and there is no need for the clock thats why clock card(CSC) falls back to SFC card mode. It means GSR can be upgraded without shutting it down.


regards
shivlu
Click Here To Read Rest Of The Post...